Fire Suppression Systems

Fire Suppression Systems

Regulatory and Design Documentation

The design and installation of a fire suppression system must follow the requirements applicable to the building, its intended use, and the selected extinguishing technology.

Relevant documentation may include:

  • DBN A.2.2-3:2014, “Composition and Content of Design Documentation for Construction,” including applicable amendments.
  • NAPB A.01.001-2014, “Fire Safety Rules in Ukraine,” in the applicable amended edition.
  • DBN V.2.5-56:2014, “Fire Protection Systems,” including applicable amendments.
  • VSN 25.09.68-85, concerning the installation and acceptance of security, fire alarm, and combined security and fire alarm systems. Its current status and applicability must be verified before use.
  • DBN V.1.1-7:2016, “Fire Safety of Construction Projects. General Requirements,” including applicable amendments.
  • The applicable Ukrainian adoption of CEN/TS 54-14, covering planning, design, installation, commissioning, use, and maintenance of fire detection and fire alarm systems. The original reference to DSTU-N CEN/TS 54-14:2009 must be checked against the currently applicable edition.
  • The Civil Protection Code of Ukraine, No. 5403-VI of 2 October 2012, as amended.
  • The applicable edition of EN 15004-1, covering gaseous fire-extinguishing systems. The original reference to EN 15004-1:2014 requires verification of its designation, edition, and applicable Ukrainian adoption.
  • DSTU 4466-8:2008, concerning a specific gaseous extinguishing agent within the gas fire-extinguishing standards series. Its full title, scope, and current status must be verified; it should not be presented as a general standard for all gaseous systems.
  • Other legislation, standards, equipment documentation, and project requirements relevant to the selected system.

Where Fire Suppression Systems Are Used

Fire suppression systems may be required in industrial, storage, commercial, and other buildings according to the applicable fire protection requirements.

Facilities such as grain storage buildings, oil and gas installations, and premises involving hazardous materials require assessment of their particular fire and explosion risks.

The presence of a hazard does not automatically make gaseous suppression the appropriate solution. The system and extinguishing agent must be selected according to the materials present, operating conditions, building characteristics, and applicable design requirements.

Design, Supply, and Installation

A fire suppression system can represent a significant investment. Its cost depends on the protected area or volume, the identified hazards, the selected technology, and the required supporting systems.

Design, equipment selection, installation, commissioning, and maintenance require appropriately qualified specialists.

Main Components of a Gaseous Fire Suppression System

The following component groups relate specifically to a gaseous fire suppression system, rather than to every type of fire suppression installation:

  • Extinguishing agent storage: Cylinders or modules containing the selected agent, with reserve supplies where required by the design.
  • Distribution pipework: Pipes, fittings, and discharge nozzles arranged according to the approved system design.
  • Detection and manual release devices: Fire detectors and manual release controls appropriate to the system.
  • Warning and notification equipment: Audible and visual warnings, including pre-discharge warnings where required.
  • Control equipment: Control and release panels, monitoring devices, and interfaces with other building systems.

The final configuration must be established for the particular application, including the necessary provisions for occupant safety.